Sampling frequency = 400 Hz
4-bit quantizer
amplitude -1.0 to 1.0

period = 1/400 = 0.0025 s = 2.5 ms

Q1

a) circle at time = 0, 2.5, 5, 7.5, 10, 12.5

b)

LevelQuantizationDigital
150.875 11111
140.75 0.8751110
130.625 0.751101
120.5 0.6251100
110.375 0.51011
100.25 0.3751010
90.125 0.251001
80 0.1251000
7-0.125 00111
6-0.25 - > -0.1250110
5-0.375 -0.250101
4-0.5 -0.3750100
3-0.625 -0.50011
2-0.75 -0.6250010
1-0.875 -0.750001
0-1 -0.8750000

c)
0, 0.45 1011
2.5, -0.45 0100
5, 0.3 1010
7.5, -0.6 0011
10, 0.5 1011/1100
12.5, 0.2 1001

d)

400 * 4 = 1600 bits/sec

Q2

a)

https://www.wolframalpha.com/input?i=%289%2F330%29log%282%2C330%2F9%29%2B%28100%2F330%29log%282%2C330%2F100%29%2B%28120%2F330%29log%282%2C330%2F120%29%2B%2865%2F330%29log%282%2C330%2F65%29%2B%2830%2F330%29log%282%2C330%2F30%29%2B%286%2F330%29log%282%2C330%2F6%29

https://www.wolframalpha.com/input?i=%28330%29%28%289%2F330%29log%282%2C330%2F9%29%2B%28100%2F330%29log%282%2C330%2F100%29%2B%28120%2F330%29log%282%2C330%2F120%29%2B%2865%2F330%29log%282%2C330%2F65%29%2B%2830%2F330%29log%282%2C330%2F30%29%2B%286%2F330%29log%282%2C330%2F6%29%29

685 bits are required

b)

854 bits are required